FEATURES
- E1 or Fractional E1 access unit
- Supports one or two data ports with selectable sync
data rates: n x 56, n x 64 kbps
- Optional sub-E1 drop & insert port for PABX
connectivity
- Failure immune sub-E1 ensuring uninterrupted
service (G.703 only)
- Data interfaces: V.35, RS-530, V.36/RS-449 or X.21
- Optional high performance built-in Ethernet bridge
- SNMP agent
- In-band remote management
- Dial-in option for remote out-of-band management
- Dial-out for alarm report
- E1 main link available with or without LTU
- Optional fiber optic main link with the following
interfaces:
- 850 nm LED for multimode
- 1300 nm LED for single mode
- 1300 nm laser for single mode
- 1550 nm laser for extended range over single mode
- Framing format (main link and sub-E1 port): 2 or 16
frames per multiframe, with or without CRC-4
- Zero suppression (main link and sub-E1 port): HDB3
- E1 interface complies with: ITU G.703, G.704,
G.706, G.732, G.823
- Enhanced diagnostics include:
- User activated local and remote loopbacks
- Integrated BER tester
- Fractional E1 in-band loop
- Stores 24 hours of E1 network performance
monitoring and last 100 alarms
- Relay activation upon alarm event
- Alarm mask configurable for any alarm
BASIC UNIT
- The basic unit includes power supply, E1 link and
one data port.
- The E1 interface is compatible with virtually all
carrier provided E1 services and meets ITU recommendations G.703, G.704,
G.706 and G.732. It supports either 2 or 16 frames per multiframe, with or
without CRC-4. Zero suppression over the line is HDB3. The integral LTU
(optional) ensures a range of up to 2 km.
- FCD-E1 can be ordered with a fiber optic link,
which eliminates the need for an external fiber optic modem. The fiber
optic link provides a secure link in hazardous or hostile environments. It
complies with ITU standards G.921 and G.956.
- Four fiber optic interfaces are available:
- 850 nm LED for use over multimode fiber at
distances up to 5 km (3 miles)
- 1300 nm LED for use over single mode fiber at
distances up to 47 km (29 miles)
- 1300 nm laser diode for use over single mode
fiber at distances up to 62 km (38 miles)
- 1550 nm laser diode for use over single mode
fiber for extended range up to 100 km (62 miles).
- Timeslot assignment is programmable, allowing data
from each data port and from the sub-E1 port to be placed into timeslots
consecutively. FCD-E1 also provides additional flexibility, by giving full
user control over the data ports timeslot allocation without restrictions.
- Multiple clock source selection ensures maximum
flexibility for supporting different applications. The E1 main link may be
clocked from the recovered receive clock, from an internal oscillator,
from one of the data ports or from the sub-E1 port.
- Immunity to hardware and power failure is provided
by bypassing the sub-E1 port to the main link (non fiber optic), ensuring
uninterrupted service to the sub-E1 port.
- FCD-E1 is available as a standalone unit. A rack
mount adapter kit enables installation of one or two standalone units,
side by side in a 19" rack.
USER INTERFACE
- The following data port interfaces can be ordered:
V.35, RS-530, V.36/RS-449 or X.21. The ports can operate in the following
clock modes:
- The optional built-in Ethernet bridge is a high
performance remote, self-learning bridge. It is ideal as a LAN extender or
segmenter over E1 link applications. The LAN table stores up to 10,000
addresses and is automatically updated. Filtering and forwarding is
performed at the maximum theoretical rate of 15,000 pps (wire speed) and
the buffer can hold 256 frames with a throughput latency of 1 frame.
Filtering can be disabled for extender or segmenter applications. The
Ethernet port is available with either 10BaseT (UTP) or 10Base2 (BNC)
interface. The Ethernet port with 10BaseT operates in full duplex mode,
while the one with 10Base2 operates in half duplex.
- The optional sub-E1 port can be configured to work
without CRC-4, while the E1 main link is working with CRC-4. This enables
connection of E1 equipment not supporting CRC-4, over an E1 network that
is working with CRC-4.
MANAGEMENT & MAINTENANCE
- Setup, control and monitoring of status and
diagnostics information can be activated via:
- Front panel LCD with three push-buttons
- ASCII terminal connected to the async control
port command line interpreter
- SNMP management connected to the async control
port.
- FCD-E1 has an internal SNMP agent and can be
controlled by any generic SNMP station or by the RADview SNMP network
management application.
- FCD-E1 supports dial-in, dial-out modem
connections. These connections can be used for remote out-of-band
configuration, monitoring and for sending callout alarm messages using the
ASCII (terminal) or SLIP protocols.
- In-band management can be performed by using the
spare bits (Sa bits) on timeslot 0 or through a dedicated timeslot that
supports proprietary protocol and Frame Relay RFC 1490. This allows setup,
monitoring and diagnostics of the remote unit. In-band access by using
spare bits on timeslot 0 is possible only if those bits are passed
transparently end-to-end.
- Maintenance capabilities include user activated
local and remote loopbacks at the E1 main link, sub-E1 and data ports. The
user can activate a BER test for each data or sub-E1 port individually.
Each data or sub-E1 port responds to an ANSI FT1 RDL (T1E1.2/93-003)
in-band loop code, generated from the remote FCD-E1 or DXC in a specific
bundle of timeslots allocated only to that port.
- When operating with CRC-4, E1 network statistics
are stored in memory according to RFC-1406. The statistic information may
be retrieved locally through the control port.
SPECIFICATIONS
FCD-E1/*/~/&/%//#+
E1 or Fractional E1 Access Unit
* |
Specify optional
drop & insert sub-link:
S1 for E1 sub-link |
~ |
Specify power supply voltage:
AC for 115 VAC and 230 VAC
48 for -48 VDC |
& |
Specify data port interface:
530 for RS-530 interface
V35 for V.35 interface
X21 for X.21 interface
449 for RS-449 interface |
% |
Specify optional 2-nd data port interface:
530 for RS-530 interface
V35 for V.35 interface
X21 for X.21 interface
449 for RS-449 interface
232 for RS-232 interface
ETU for UTP Ethernet bridge (10BaseT)
ETB for BNC Ethernet bridge (10Base2) |
|
Specify optional line interface:
LTU for integral Line Termination Unit |
#+ |
Specify optional optical interface: |
# |
ST for ST connector
SC for SC connector
FC for FC/PC connector |
+ |
85 for 850 nm, multimode
13 for 1300 nm, single mode
13L for 1300 nm, single mode, laser diode
15L for 1550 nm, single mode, laser diode
(Default is G.703 electrical interface) |
Cables
The following cables convert the 25-pin channel
connector into the respective interface. Cable length is 2m (6 ft), unless
otherwise indicated.
CBL-HS2V1 to connect a V.35 DTE using DCE clock
mode*
CBL-HS2V2 to connect a V.35 DCE using DTE1
clock mode*
CBL-HS2V3 to connect a V.35 DCE using DTE2
clock mode*
CBL-HS2R1 to connect an RS-449 (V.36) DTE using
DCE clock mode*
CBL-HS2R2 to connect an RS-449 (V.36) DCE using
DTE1 clock mode*
CBL-HS2R3 to connect an RS-449 (V.36) DCE using
DTE2 clock mode*
CBL-HS2X1 to connect an X.21 DTE using DCE
clock mode*
* |
DCE clock mode: FCD-E1 provides both
transmit and receive clocks
DTE1 clock mode: FCD-E1 provides transmit
clock, attached DCE provides receive clock
DTE2 clock mode: attached DCE provides both
transmit and receive clocks |
ORDERING
FCD-E1/48/1/X
FCD-E1/48/2/V
FCD-E1/48/ETU/V
FCD-E1/AC/1/530
FCD-E1/AC/1/C/V
FCD-E1/AC/1/C/X
FCD-E1/AC/1/ST/85
FCD-E1/AC/1/V
FCD-E1/AC/1/X
FCD-E1/AC/1/X21/ST/85
FCD-E1/AC/2/530
FCD-E1/AC/2/C/ETU/530
FCD-E1/AC/2/C/V
FCD-E1/AC/2/R
FCD-E1/AC/2/V
FCD-E1/AC/2/V/ST13
FCD-E1/AC/2/V/X
FCD-E1/AC/C/ETU/V
FCD-E1/AC/ETU/530
FCD-E1/AC/ETU/V
FCD-E1/S1/48/1/V
FCD-E1/S1/48/2/V
FCD-E1/S1/48/ETU/C/V
FCD-E1/S1/48/ETU/V
FCD-E1/S1/AC/1/530
FCD-E1/S1/AC/1/C/530
FCD-E1/S1/AC/1/C/V
FCD-E1/S1/AC/1/V
FCD-E1/S1/AC/2/530
FCD-E1/S1/AC/2/V
FCD-E1/S1/AC/2/V/X
FCD-E1/S1/AC/ETU
FCD-E1/S1/AC/ETU/V
FCD-E1A/S1/AC/UTP/530
FCD-E1A/S1/AC/UTP/V35
FCD-E1A/S1/AC/V24/V35/232
FCD-E1I/AC/V35
FCD-E1I/S1/AC/L/V/FO1
FCD-E1L/B/AC/V35
FCD-E1L/U/AC/V35
FCD-E1M/AC/U/V35
FCD-E1M/S1/AC/U/V35
APPLICATION

Figure 1 - Extended Ethernet Management over E1 Network

Figure 2 - Connection of LAN Traffic together with PABX Traffic to E1
Network

Figure 3 - SDH Access Solution for Multiple Remote Sites
|