Features
- The ASM-10/8, Short Range Modem, operates full or
half duplex with synchronous or asynchronous transmission format over
unconditioned dedicated lines. ASM-10/8 has an extended range of up to 28
km (17.5 miles) and operates at eight selectable data rates up to 19.2
kbps.
- The modem uses conditioned differential diphase
modulation (EUROCOM Std. D1), which provides immunity to background noise,
and eliminates normal line distortion for efficient transfer of serial
data over twisted pair cable. ASM-10/8 is coupled to the dedicated line
through isolation transformers which, in conjunction with other circuitry,
protect against AC or DC overvoltage. The protection circuitry enables
operation even when DC is connected to the line.
- Transmit level and impedance are independently
selectable. Transmit timing can be provided internally, or can be derived
externally from the data terminal or from the receive signal. Receive
timing is regenerated from the data. Line communication is always
synchronous. When set to async mode, ASM-10/8 performs async to sync
conversion in compliance with ITU V.14 standard.
- ASM-10/8 features V.54 diagnostic capabilities for
performing local analog loopback, local and remote digital loopback. The
operator at either end of the line may test both modems and the line when
in the digital loopback mode. The loopback is controlled by either front
panel pushbuttons or via Pins 18 and 21 of the V.24/RS-232 interface. A
selectable option allows insertion of a delay into the data stream so that
the V.54 loops are not carried across the network.
- ASM-10/8 is available as a desk-top unit or as a
rack-mount card for a 19" rack. The rack can carry up to 14 of the
ASM-10/8 cards. The rack-mount card can detect and indicate power failure
on the remote stand-alone unit. The front panel RPF indicator lights if
remote power failure occurs.
Application

ASM10/8/R ASM10/8/SA/115 ASM10/8/SA/230
ASM10/8/SA/48
|