Digi
DataFire® RAS
Product Specifications
|
Scalable Server-Based Remote Access Concentrators by
Digi for Analog and Digital
Connections
jump to Product info page
High density access concentrator (8, 24, 30, 48 or 60 channels) | > Advanced DSPs |
> Supports V.90, K56flex, ISDN, and advanced fax applications | > Universal PCI and CompactPCI server compliance |
> Scalable, modular, and field-upgradable | > Wide O/S and third-party application suppport |
Product Specifications
Modem Standards Compatibility | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
56 Kpbs > Rockwell/Lucent K56flex standard > ITU V.90 standard V.34 Telephony (CTI) modes ![]() > ITU G.711 µ-Law/A-Law Companding and Expanding > DTMF generation and detection > Caller ID and Call Progress Data Modems ![]() > ITU-T V.34: 33,6000-2400 (TCM) > ITU-T V.34 bis > ITU-T V.32 bis: 14,400, 12000, 7200 (TCM) > ITU-T V.32 bis: 9600 (TCM), 4800 (QAM) > ITU-T V.24 bis > ITU-T V.23: 600/75, 1200/75 (FSK) > ITU-T V.22 bis: 2400 (QAM) > ITU-T V.22: 1200 (DPSK) > ITU-T V.21: 300 (FSK) > Bell 212a: 1200 (DPSK) > Bell 103: 300 (FSK) > TIA TSB37-A > TIAS TSB38 Fax Modes > ITU-T V.17: 14,400 > ITU-T V.29: 9600 > ITU-T V.27 ter: 4800 > ITU-T V.21 channel 2: 300 Compression and Error Correction > V.42 bis > MNP Class 2 > MNP Class 4 > MNP Class 5 > V.42 Error Correction (LAPM and MNP) |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Bus Capacity | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
Unlimited
DataFire and/or AccelePort adapters can work together in the same server.
Practical limitations are dependent on the capability of the server
platform. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
RAS Family API | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
All of the Digi
DSP-based RAS products conform to the same, highly flexible, well documented
API. With this API, developers can write drivers to proprietary operating
systems, or to standard operating systems with proprietary extensions. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Fax Command Set Standards | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
> Group 3 FAX
Class 1 > Group 3 FAX Class 2 > Group 3 Fax Class 2.0 > Class 2.0 Error Correction Mode (ECM) > Copy Quality Checking and Receive Quality Thresholds > Image Compression > Adaptive Answering > TSI Banner > Distinctive Ring > Caller ID (Automatic Number Identification - ANI) > IS-101 Voice Command Set Fax Compression Formats: All optional Class 2.0 data format conversions are supported including: ![]() > Normal Image > Fine Image > 1D Image Conversion > 2D - MR (Modified Read) Image Conversion > 2D - MMR (Modified Modified Read) Image Conversion |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
T1/E1 Specifications | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
T1
Supervision Modes![]() > Ground Start Signaling > Wink Start Signaling > Immediate Start Signaling > Loop Start Signaling E1 Supervision Modes ![]() > CCS with CRC4 ITU G.704 > CAS with CRC4 ITU G.704 > CRCA with Remote End Block Error Signaling > R2 Signaling (future enhancement) |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
ISDN Specifications | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
![]() > ISDN data link layer ITU-T Q.921 > ISDN call control signaling ITU-T Q.932/I.451 > Novell NetWare CAPI |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Features | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Dimensions | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
DataFire RAS 24 PT1, 48 PT2, 30 PE1, 60 PE2 (PCI)
> Length: 12.283 inches (31.199 cm) > Width: 4.200 inches (10.668 cm) DataFire RAS Daughter Card(s) 24 PTM, 30 PEM > Length: 7.1 inches (18.034 cm) > Width: 3.80 inches (9.652 cm) DataFire RAS 4 (B4 ST and B4 U) (PCI) > Length: 12.283 inches with metal retainer (23.39 cm) > Width: 4.20 inches (10.668 cm) DataFire RAS 24 PT1, 48 PT2, 30PE1, 60 PE2 (CompactPCI) > Length: 6.3 inches (16.002 cm) > Width: 9.19 inches (23.342 cm) |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Power Requirements | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
DataFire RAS 24/48/30/60 (PCI) (PT1/PE1/PT2/PE2)
> 2.56 A 5.0 V typical (PT1) > 2.77 A 5.0 V typical (PE1) > 3.51 A 5.0 V typical (PT2) > 3.94 A 5.0 V typical (PE2) DataFire RAS 4 (B4 U and B4 ST) > 1.13 A 5.0 V typical (B4 ST) > 1.21 A 5.0 V typical (B4 U) DataFire DSP 24/48/30/60 (CompactPCI) (PT1/PE1/PT2/PE2) > 11.65 Watts +/- 5% typical (PT1) > 12.175 Watts +/- 5% typical (PE1) > 19.35 Watts +/-5% typical (PT2) > 24.35 Watts +/-5% typical (PE2) |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Operating System Support | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
Microsoft > Windows 2000 > Windows NT 4.0 Service Pack 4 or higher Novell > NetWare 4.2 > NetWare 5.0 > NetWare 5.1 SCO > UnixWare 2.x, 7.x > OpenServer 5.x Sun > Solaris 2.6, 7, 8 (support for analog/modem fax connections only) Linux |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Environmental | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
> Ambient
Temperature: 0° C to 50° C (32° F to 122° F) > Relative Humidity 5% to 90%, non-condensing > Air Movement 30 CFM Forced > Altitude 0 to 3,660 M (0 to 12,000 Feet) |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Certification | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
DataFire RAS 24 PT1, 48 PT2, 30 PE1, 60 PE2 DataFire DSP 24 PT1, 48 Pt2, 30 PE1, 60 PE2 (CompactPCI) Emissions Specifications and Immunity ![]() > USA: FCC Part 15, Radiated Emissions Specification, Supbpart 3, Class B > CSA C108.8-M83, Class B > CISPR 22, Class B > Canada: ICES 003 Radiated Emissions Specification > Europe: EN55022 Radiated Emissions Specification > VCCI Radiated Emissions Specification > AS3548 Radiated Emissions Specification > En50082 Immunity Safety ![]() > USA: UL Recognized, UL 1950 > Canada: CSA Certified, CSA C22.2 No. 950 > Europe: EN60950 > CE mark > Australia: AS3260 Telecom ![]() > USA: FCC Part 68 > Canada: CS03 > Europe: I-CTR4 (NET 5) > Japan: Jate Blue Book > Australia: TS038 DataFire RAS 4 B4 ST and B4 U (PCI) Emissions and Immunity ![]() > USA: FCC Part 15, Subpart 3, Class B > CSA C108.8-M83, Class B > CISPR 22, Class B > VCCI 2 > EN55022-1 > IEC 801-2, 801-3, 801-4, 801-5, 801-6 Safety ![]() > USA: UL Recognized, UL 1950 > Canada: CSA Certified, CSA C22.2 No. 220 > Europe: IEC 380/950 Safety (TUV) > CE mark Telecom ![]() > USA: FCC part 68 > Canada: CS03 > Europe: I-CTR4 (NET 5) > Net 3 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Product and Part Numbers
DataFire RAS 4/24/48/30/60 |
> | DataFire RAS 24 PT1 | #77000593 | |||||
![]() |
|||||||
> | DataFire RAS Dgtr Card 24 PTM | #77000594 | |||||
![]() |
|||||||
> | DataFire RAS 48 PT2 | #77000597 | |||||
![]() |
|||||||
> | DataFire RAS 30 PE1 | #77000599 | |||||
![]() |
|||||||
> | DataFire RAS Dgtr Card 30 PEM | #77000600 | |||||
![]() |
|||||||
> | DataFire RAS 60 PE2 | #77000603 | |||||
![]() |
DataFire RAS 4 |
> | DataFire RAS 4 B4ST | #77000605 | |||||
![]() |
|||||||
> | DataFire RAS 4 B4U | #77000606 | |||||
![]() |
I