MIU-PowerPort
- VDC power
12 Volt DC Power Modem with sleep modem
When not on line, the dial up modem automatically go into a power down mode and consumes only 5m amps while inactive.
|
|
has designed modems that work
in "remote" remote sites with very low failure rates. These devices
work where other modems roll over and die. When a service call to a remote site
can mean an all day trip these modems are the ideal solution.
The MIU/PowerPort is an industrial grade modem that can be
powered directly through the RS232 (DB25) data interface port or power jack.
MIU/PowerPort can be powered by delivering +5VDC (regulated) through pin 10 of the DB25. An optional 12VDC version is also available. Alternatively, an external jack allows the MIU/PowerPort to be powered from a wall transformer or other low voltage AC or DC power source.
When not on line, the dial up MIU/PowerPort modems automatically go into a power down mode and consumes only 5m amps while inactive.
The MIU/PowerPort is available with various modulations, including...
...and operates over dial-up and 2 or 4-wire leased lines at full or half duplex as appropriate.
The MIU/PowerPort has a sister product, the MIU/PowerPack, which is powered from an internal, rechargeable Ni-Cad battery. The battery draws its charging current from the DTE’s RS232 interface or an optional solar panel. For more information, ask for the MIU/PowerPack brochure and specifications.
The MIU/PowerPort is fully Hayes AT command set compatible with programmable S-registers.
All models will operate in temperatures from -40 to 85oC and are surge protected on the analog line up to 5kV.
Technical
Specifications |
MIU/PowerPort 202T xx |
MIU/PowerPort 2.4 |
MIU/PowerPort 9.6 & 9.6L |
MIU/PowerPort 14.4 & 14.4L |
MIU/PowerPort 28.8 |
Modem
Line Speeds:
Asynchronous |
0 - 1200bps |
2400, 1200, 300bps |
2400, 1200, 300bps |
14400, 9600, 4800, 2400, 1200, 300bps |
28800, 14400, 9600, 4800, 2400, 1200, 300bps |
DTE Rates above modem line speeds (ie; with data compression) |
- |
- |
19200, 9600, 4800bps |
57.6, 38.4, |
115.2, 57.6, |
Protocols |
Bell 202 |
V.22bis, V.22 |
V.22bis, V.22 |
V.32bis, V.32 V.22bis, V.22 Bell212A, Bell103 |
V.34, V.32bis, V.32
V.22bis, V.22 |
Dial Up |
No |
Yes |
Yes (Model 9.6) |
Yes (Model 14.4) |
Yes |
2 Wire Leased Line |
Yes1 |
No |
Yes (Model 9.6L2) |
Yes (Model 14.4L2) |
No |
4 Wire Leased Line |
Yes1 |
No |
Yes (Model 9.6L2) |
Yes (Model 14.4L2) |
No |
Compatibility |
n/a |
Hayes™ Extended AT Command Set |
|||
Error
Correction/ Data Compression |
None |
None |
MNP 2, 4, 5 & 10 |
||
Power Requirements |
+5 VDC ±5% in through Pin
10 on the DB25 Data Port |
||||
Current Consumption |
128mA +5VDC 71mA 12VDC |
64mA +5VDC 35mA 12VDC |
100mA +5VDC 56mA 12VDC |
219mA +5VDC 123mA 12VDC |
287mA +5VDC 160mA 12VDC |
Sleep Mode |
Dial up modems
can be factory set to automatically fall into "Power Down"
mode |
||||
Digital Port |
RS232 with DB25 Female Connector |
||||
Analog Port |
RJ11 |
||||
Surge
Protection
(Analog Port) |
3.75kVac |
5kVac |
5kVac |
3.75kVac |
3.75kVac |
Environment |
-40oC to +85oC, 0 to 95% humidity (non-condensing) |
||||
Case Size |
5-3/8" x 4" x 1-3/8" |
||||
Certifications |
FCC Part 68 Class A, Industry Canada Certified |
Important notes regarding leased line operation: 1 Bell202T is half or full duplex, suitable for point-to-point and multipoint applications. 2 The standard 9.6L & 14.4L models are 4-wire, full or half duplex, point-to-point only. 2-wire, full duplex, point-to-point available on special order.