BAT Electronics |
LIFETIME WARRANTY
ez-t1-t1 csu/dsu | EZ-FT1-Factional T1 CSU/DSU | EZ-56K-56Kbps CSU/DSU |
su5696-9.6 to 56kbps csu/dsu| DUAL-1 Switched Digital Service| VRT-1-56Kbps CSU/DSU
vrt-2 2 port 56kbps csu/dsu| VRT-4 4 port 56Kbps CSU/DSU| vrl-1 multi-rate csu/dsu| SPEAK EZ-2-voice & data port 56Kbps CSU/DSU
PRODUCT FEATURES
SU5696/ER-DC
see the su5696 sheet for specifications
extended temperature range & DC power - 9.6 to 56Kbps CSU/DSUJust released from BAT Electronics an extended temperature range CSU/DSU. This product is designed for outdoor industrial applications where more severe environmental conditions are encountered. The product finds applications in power and gas line distribution systems, as well as numerous process control systems, The product is based on our SU-5696, but uses extended temperature range parts giving a temperature range of -30 to +150 degrees Fahrenheit. All other specifications remain the same. The product is available in a desk top enclosure or rack mounted using the RM-10.
Now available with a power input option of 12, 24 or 48 VDC. The input floats so ground loops are eliminated. The input total power requirement is under 3.5 watts. Power input can be from solar cells or regular battery. Wide voltage swings can be tolerated. Contact your distributor for cost and lead times.
SU-5696/ER DC POWERED
9.6 to 56Kbps CSU/DSUSU-5696 (SEVERE ENVIRONMENT) SPECIFICATIONS
Data rate: 56K,19.2K, 9.6K
Operating Modes: Dedicated Digital Service, for point to point or multipoint operation.
Standard Features: IN Service LED, internal timing, permanent RTS (user option).
Non-volatile parameter storage.
Dual interfaces
Internal pattern generator.
Proven design
Test Features: Front panel status and test indicators.
Front panel Push button selects the following test modes:
Self Test, Digital Loop, Local Loop, Remote Loop.
Responds to Bell defined loop backs.
Internal pattern generator.
DC Power 12, 24, 48 VDC on terminal board
Environment: - 40 to +60 C, up to 99% humidity
Physical: Height 2.5 in.
Width 8.0 in.
Depth 6.25 in.
MBTF in excess of 100,000 hour
CUSTOMER INTERFACE
Connectors: One V.35 and one RS-232 DB-25 connector.
Configuration, Speed Interface Sync ASYNC
56-OK V.351 RS-232YES YES
1 9.2K Same YES YES
9.6K Same YES YES
Signals are present at both connectors.
Data Format: Synchronous, Asynchronous (speed dependent)
LINE INTERFACE
Line Interface, Standard registered RJ-48s jack on rear panel.
RX Levels: Supports attenuation of greater than 44db. (10 db better than telco specs)
Equalization: Fully automatic and adaptive, no need for user adjustments
Digital service 56K, 19.2K, 9,6K
GENERAL | |
Data Rate: | 1.544M bps |
Operating Modes: | Line Codes: AMI/B8ZS. Framing: D4/ESF (ATT or ANSI) |
Standard Features: | Local and remote test with internal pattern generator. Front panel LED display aids in testing, monitoring and trouble shooting. Full performance monitoring per ANSI and Bellcore requirements, including 24 hour network with error second information. All reports available via command port. |
CUSTOMER INTERFACE | |
Connectors: | One V.35 for DTE interface. |
One DB-25 for RS-530 for DTE interface. | |
One DB-25 for command port. (Supports RS-232 PC or terminal) | |
Speed: | 1.544Mbps |
Mode: | Synchronous |
PHYSICAL | |
Size: | Height..............2.5 In. |
Width...............8.0 In. | |
Depth...............6.25 In. | |
Power: | 117 VAC +/- 10%, 60 HZ. 5 watts |
Environment: | 0 to 50 C, up to 95% humidity |
Rack Mount: | Fits in current BAT Rack |
LINE INTERFACE | |
Line Interface: | Standard registered jack on rear panel. |
Equalization: | Fully Automatic and adaptive, no need for user adjustments. |
Line Requirements: | Digital service at T-1 speed. |
GENERAL | |
Data Rate: | T-1 or fractional T-1 speeds |
Operating Modes: | Line Codes: AMI/B8ZS. |
Framing: D4/ESF (ATT or ANSI) | |
Standard Features: | Local and Remote test with internal pattern generator |
Front panel LED display aids in testing, monitoring, and trouble shooting. | |
Full performance monitoring per ANSI and Bellcore requirements including 24 hour network error second information. | |
All reports available via command port. | |
CUSTOMER INTERFACE | |
Connectors: | One V.35 for DTE interface |
One DB.25 for RS-530 for DTE interface | |
One DB-25 for command port. (Supports RS-232 PC or terminal) | |
Speed: | Nx56 or Nx64Kbps N=1 to 24. Any selection of DSO's ok. |
Mode: | Synchronous |
PHYSICAL | |
Size: | Height..............2.5 In. |
Width...............8.0 In. | |
Depth...............6.25 In. | |
Power: | 117 VAC +/- 10%, 60HZ . 5 watts |
Environment: | 0 to 50 C, up to 95% humidity |
Rack Mount: | Fits in current BAT Rack |
LINE INTERFACE | |
Line Interface: | Standard registered jack on rear panel. |
Equalization: | Fully automatic and adaptive, no need for user adjustments. |
Line Requirements: | Digital service at T-1 or fractional T-1 speeds. |
GENERAL | |
Data Rate: | 56,000 BPS |
Operating Modes: | Dedicated Digital Service, for point to point operation. |
The product may also be used as a Limited Distance Modem. | |
Standard Features: | IN Service LED, internal timing, permanent RTS (user option). |
Non-volatile parameter storage. Dual interfaces. | |
Internal pattern generator. Proven design. | |
Test Features: | Ten front panel status and test indicators. Front panel push button selects the following test modes: Self Test, Digital Loop, Local Loop, Remote Loop |
Responds to Bell defined loop backs. Internal pattern generator. | |
AC Power: | 117 VAC +/- 10%, 60Hz, 12w. |
Environment: | 0 to 50 C, up to 95% humidity. |
Physical: | Height.................2.5 in. |
Width.................8.0 in. | |
Depth.................6.25 in. | |
CUSTOMER INTERFACE | |
Connectors: | One V.35 and one DB-25 connector. |
Configuration: | Speed.........................56.0K |
Interface......................V.35/ RS-232 | |
Sync............................YES | |
Signals are present at both connectors | |
Data Format: | Synchronous |
LINE INTERFACE | |
Line Interface: | Standard registered RJ-48s jack on rear panel. |
RX Levels: | Supports attenuation of greater than 48db. (14 db better than telco specs) |
Equalization: | Fully automatic and adaptive, no need for user adjustments. |
Line Requirements: | Digital Service at 56K. |
GENERAL | |
Data Rate: | 56K, 19.2K, 9.6K. |
Rate Selection: | Auto Adaptive |
Operating Modes: | 8 wire termination of Dataphone Digital Service (DDS) in point to point or multi-point applications. |
May also be used as Limited Distance Modem in point to point applications. | |
Standard Features: | IN Service LED, internal timing, DDS slave timing, permanent RTS, (user option). |
Auto Adaptive rate selection. | |
Test Features: | Ten front panel status and test indicators. Front panel push button selects the following test modes: Self Test, Digital Loop, Local Loop, Remote Loop |
Responds to Bell defined CSU and DSU loop backs from the Central Office. | |
Internal pattern generator | |
Front panel multi-color LED displays current line rate. | |
AC/DC Power: | 117 VAC +/- 10%, 60 Hz, 12w. & 12 - 24 - 48 volt DC power |
Environment: | 0 to 50 C, up to 95% humidity. |
Physical: | Height..............2.50 In. |
Width...............8.00 In. | |
Depth...............6.25 In. | |
CUSTOMER INTERFACE | |
Interface: | V.35 and RS-232 with both connectors and interface circuits. |
Data Format: | Any Synchronous Format |
Asynchronous format: supports 10/11 bit ASCII | |
LINE INTERFACE | |
Interface: | 8 wire termination on rear panel RJ-48s. |
Modulation: | Bipolar return to zero |
RX levels: | Supports at least 40 db attraction (exceeds Telco requirements by 6 db) |
Equalization: | Automatic, no user adjustment needed |
GENERAL | ||||
Line Rate: | 56,000 bps | |||
Operating Modes: | Switched Digital Service (SDS) in point-to-point applications. | |||
Dedicated point-to-point or multi-point applications. | ||||
Standard Features: | IN Service LED, internal timing, permanent RTS (user option) | |||
Test Features: | Ten front panel status and test indicators. Front panel push button selects the following test modes: Self Test, Digital Loop, Local Loop, Remote Loop. | |||
Responds to Bell defined loop backs from the Central Office. | ||||
Internal pattern generator. | ||||
AC Power: | 117 VAC +/- 10%, 60Hz, 12w. | |||
Environment: | 0 to 50 C, up to 95% humidity. | |||
CUSTOMER INTERFACE | ||||
Connectors: | One V.35 and two DB-25 connectors. | |||
Configuration: | Speed | Interface | Sync | Async |
57.6K | V.35/ RS-232 | NO | YES | |
56.0K | V.35/ RS-232 | YES | YES | |
38.4K | V.35/ RS-232 | YES | YES | |
19.4K | V.35/ RS-232 | YES | YES | |
9.6K | V.35/ RS-232 | YES | YES | |
4.8K | V.35/ RS-232 | YES | YES | |
2.4K | V.35/ RS-232 | YES | YES | |
1.2K | V.35/ RS-232 | YES | YES | |
Signals are present at both connectors at all speeds | ||||
Data Format: | Synchronous or Asynchronous | |||
Configuration Commands: | User may configure and dial the DUAL-1 using "standard command set". | |||
Parameters can be remotely elected and set on dial or dedicated lines. | ||||
Dial Method: | "Standard" commands via data port or auxiliary DB-25 connector provided. | |||
Optional RS-366 dialing via auxiliary DB-25 connector. | ||||
Parameter Storage: | Non-volatile. | |||
Line Interface: | Standard Registered RJ-48s jack on rear panel. | |||
RX Levels: | Supports attenuation of greater than 44db. (10 db better than telco specs) | |||
Equalization: | Fully automatic and adaptive, no need for user adjustments. | |||
Line Requirements: | Switched 4 wire digital service or dedicated 4 wire digital service. |
GENERAL | ||||
Line Rate: | 56,000 bps | |||
Operating Modes: | Dataphone Digital Service (DDS) in point to point or multi-point applications. | |||
May also be used as Limited Distance Modem in point to point applications. | ||||
Standard Features: | IN Service LED, internal timing, DDS slave timing, permanent RTS (user option). | |||
Test Features: | Ten front panel status and test indicators. Front panel push button selects the following test modes: Self Test, Digital Loop, Local Loop, Remote Loop. | |||
Responds to Bell defined CSU and DSU loop backs from the Central Office. | ||||
Internal pattern generator. | ||||
AC Power: | 117 VAC +/- 10%, 60Hz, 12w. | |||
Environment: | 0 to 50 C, up to 95% humidity. | |||
Physical: | Height..................2.50 In. | |||
Width...................8.00 In. | ||||
Depth...................6.25 In. | ||||
CUSTOMER INTERFACE | ||||
Connectors: | Both V.35 and RS-232 connectors provided. | |||
Configuration: | Speed | Interface | Sync | Async |
56.0K | V.35 | YES | NO | |
38.4K | RS-232 | YES | YES | |
19.2K | RS-232 | YES | YES | |
9.6K | RS-232 | YES | YES | |
4.8K | RS-232 | YES | YES | |
2.4K | RS-232 | YES | YES | |
1.2K | RS-232 | YES | YES | |
Signals are present at both connectors regardless of data rate. | ||||
Data Format: | Synchronous or Asynchronous (7/8data bits one stop bit) | |||
LINE INTERFACE | ||||
Interface: | Standard registered RJ-48s jack on the rear panel. | |||
Modulation: | Bipolar return to zero. | |||
Impedance: | 135 ohm +/- 10% | |||
TX level (135ohm load): | 56,000....1.4v peak | |||
RX levels: | Supports at least 40 db attenuation (exceeds Telco requirements by 6 db) | |||
Equalization: | Automatic, no user adjustment needed. |
GENERAL | |||||||
Line Rate: | 56,000 bps | ||||||
Operating Modes: | Dataphone Digital Service (DDS in point to point or multi-point applications. | ||||||
May also be used as a Limited Distance Modem in point to point applications | |||||||
Test Features: | Ten front panel status and test indicators. Front panel push button selects the following modes: Self Test, Digital Loop, Local Loop, Remote Loop. | ||||||
Responds to Bell defined CSU and DSU loop backs from the Central Office. | |||||||
Internal pattern generator. | |||||||
AC Power: | 117 VAC +/- 10%, 60 Hz, 12w. | ||||||
Environment: | 0 to 50 C, up to 95% humidity. | ||||||
Physical: | Height......2.50 In. . | ||||||
Width.......8.00 In. | |||||||
Depth.......6.25 In. | |||||||
CUSTOMER INTERFACE | |||||||
Connectors: | One V.35 and Two RS-232 connectors provided. | ||||||
Configurations: | |||||||
MODE 1 | |||||||
CHANNEL 1 | CHANNEL 2 (not used in MODE 1) | ||||||
Speed | Interface | Sync | Async | Speed | Interface | Sync | Async |
56.0K | V.35 | YES | NO | N/A | N/A | N/A | N/A |
MODE 2 | |||||||
CHANNEL 1 | CHANNEL 2 | ||||||
Speed | Interface | Sync | Async | Speed | Interface | Sync | Async |
38.4K | RS-232 | YES | YES | 9.6K | RS-232 | YES | YES |
19.2K | RS-232 | YES | YES | 4.8K | RS-232 | YES | YES |
9.6K | RS-232 | YES | YES | 2.4K | RS-232 | YES | YES |
4.8K | RS-232 | YES | YES | 1.2K | RS-232 | YES | YES |
MODE 3 | |||||||
CHANNEL 1 | CHANNEL 2 | ||||||
Speed | Interface | Sync | Async | Speed | Interface | Sync | Async |
19.2K | RS-232 | YES | YES | 19.2K | RS-232 | YES | YES |
9.6K | RS-232 | YES | YES | 9.6K | RS-232 | YES | YES |
4.8K | RS-232 | YES | YES | 4.8K | RS-232 | YES | YES |
2.4K | RS-232 | YES | YES | 2.4K | RS-232 | YES | YES |
Channel 2 speeds are independent of Channel 1 speed settings in modes 2 and 3 | |||||||
LINE INTERFACE | |||||||
Interface: | Standard registered RJ-48s jack on the rear panel. | ||||||
Modulation: | Bipolar return to zero. | ||||||
Impedance: | 135 ohm +/- 10%. | ||||||
TX Level (135 ohm load): | 56,000 bps.....1.4v peak. | ||||||
RX Levels: | Supports at least 40 db attenuation (exceeds Telco requirements by 6 db) | ||||||
Equalization: | Automatic, no user adjustment needed. |
GENERAL | ||||
Line Rate: | 56,000 bps | |||
Operating Modes: | Dataphone Digital Service (DDS) in point to point applications | |||
May also be used as Limited Distance Modem. | ||||
Test Features: | Nine front panel status and test indicators. Front panel push button selects the following test modes: Self Test, Digital Loop, Local Loop, Remote Loop. | |||
Supports CSU and DSU loop from the Central Office | ||||
Internal pattern generator. | ||||
AC Power: | 117 VAC +/- 10%, 60 Hz, 12w. | |||
Environment: | 0 to 50 C, up to 95% humidity. | |||
Physical: | Height 2.50 In | |||
Width 8.00 In | ||||
Depth 6.25 In | ||||
CUSTOMER INTERFACE: | ||||
Connectors: | Four RS-232 connectors provided. | |||
Modes: | ||||
MODE 1 | ||||
CHANNEL | CHANNEL 2 | CHANNEL 3 | CHANNEL 4 | |
Speed | Speed | Speed | Speed | |
38.4K | 9.6K | Not Usable | Not Usable | |
MODE 2 | ||||
CHANNEL 1 | CHANNEL 2 | CHANNEL 3 | CHANNEL 4 | |
Speed | Speed | Speed | Speed | |
19.2K | 19.K | 9.6K | Not Usable | |
MODE 3 | ||||
CHANNEL 1 | CHANNEL 2 | CHANNEL 3 | CHANNEL 4 | |
Speed | Speed | Speed | Speed | |
19.2K | 9.6K | 9.6K | 9.6K | |
MODE 4 | ||||
CHANNEL 1 | CHANNEL 2 | CHANNEL 3 | CHANNEL 4 | |
Speed | Speed | Speed | Speed | |
9.6K | 9.6K | 9.6K | 9.6K | |
ALL CHANNELS CAN RUN SYNC OR ASYNC | ||||
LINE INTERFACE | ||||
Interface: | Standard registered RJ-48s jack on the rear panel. | |||
RX Levels: | Supports at least 40 db attenuation (exceeds Telco requirements by 6 db). | |||
Equalization: | Automatic, no user adjustment needed. |
GENERAL | |||||
Line Rate: | 56K, 19.2K, 9.6K auto adaptive | ||||
Operating Modes: | Dataphone Digital Service (DDS) in point to point or multi-point applications. | ||||
May also be used as Limited Distance Modem. | |||||
Standard Features: | Slave and master timing. | ||||
Async operation. | |||||
Integral diagnostics. | |||||
Adaptable terminal side rates. | |||||
Both RS-232 and V.35 connectors and interfaces provided. | |||||
Test Features: | Ten front panel status and test indicators. Front panel push button selects the following test modes: Self Test, Digital Loop, Local Loop, Remote Loop. | ||||
Responds to Bell defined CSU and DSU loop backs from the Central Office. | |||||
Internal test pattern generator. | |||||
AC Power: | 117 VAC +/- 10%, 60 Hz, 12w | ||||
Environment: | 0 to 50 C, up to 95% humidity. | ||||
Physical: | Height..............2.50 In. | ||||
Width...............8.00 In. | |||||
Depth...............6.25 In. | |||||
CUSTOMER INTERFACE | |||||
Connectors: | Both V.35 and RS-232 connectors and interfaces provided. | ||||
Operating Modes: | |||||
Mode 1: | Telco Line Speed 56K | ||||
Terminal Config.: | Speed | Interface | Sync | Async | |
56.0K | V.35 | YES | NO | ||
38.4K | RS-232 | YES | YES | ||
19.2K | RS-232 | YES | YES | ||
9.6K | RS-232 | YES | YES | ||
4.8K | RS-232 | YES | YES | ||
2.4K | RS-232 | YES | YES | ||
1.2K | RS-232 | YES | YES | ||
MODE 2: | Telco Line Speed 19.2K | ||||
Terminal Config.: | 19.2K | RS-232 | YES | YES | |
MODE 3 | Telco Line Speed 9.6K | ||||
Terminal Config.: | 9.6K | RS-232 | YES | YES | |
Data Format: | Synchronous or Asynchronous (7/8 data bits one stop bit) | ||||
LINE INTERFACE | |||||
Interface: | Standard registered RJ-48s jack on the rear panel. | ||||
RX Levels: | Supports 40 db attenuation (exceeds requirements by 6 db). | ||||
Equalization: | Automatic, no user adjustment needed. |
CUSTOMER | ||
DATA INTERFACES: | Both V.35 and RS-232 connectors and interfaces are provided. | |
VOICE INTERFACES: | Three separate voice interfaces and jacks are provided. | |
The SPEAK EZ-2 can accommodate a telephone, PBX tie trunk, or a PBX extension line. | ||
All of the necessary couplers are provided and are internal to the device. | ||
FAX SIGNALING: | The SPEAK EZ-2 supports FAX through its voice port. | |
SIGNALING: | Audible remote ringing and dial tone and touch tone propagation. Integral ringer provided. | |
CONFIGURATIONS: | VOICE SPEED | DATA SPEED |
16K | 38.4K OR 19.2K | |
32K | 19.2K OR 9.6K | |
REAR PANEL: | The rear panel contains the following: | |
3] Voice Jacks | 1] V.35 Connector | |
1] RS-232 Connector | 1] DIP to set options | |
1] Telephone line connection | 1] Power connection | |
CSU / DSU | ||
LINE RATE: | 56K BPS | |
LINE INTERFACE: | Standard DDS service. Supports up to 48db of attenuation. | |
FEATURES: | Internal external timing, permanent RTS. | |
TEST FEATURES: | Supports CSU/DSU loop as well as standard BAT remote test features. | |
Front panel selector enables the test capabilities including local loop and digital loop. | ||
Internal test pattern generator supplied. | ||
GENERAL | ||
AC POWER: | 117 VAC +/- 10%, 60 HZ, 30 WATTS | |
POWER ISOLATION: | Terminal equipment interfaces operate from their own isolated power. This eliminates telephone to computer system ground loops. | |
ENVIRONMENT: | 0 to 50 C, up to 95% humidity. | |
PACKAGING: | Table top enclosure, with rack mount capability. |
DDS SP | VRT-4 | VRT-2 | VRT-1 | VRL-1 | SU5696 | SU56K+ | SU56K | SU64K+ | VRT-1/64K |
64.0K | . | . | . | . | . | . | . | X | X |
56.0K | X | X | X | X | X | X | X | . | . |
19.2K | . | . | . | X | X | . | . | . | . |
9.6K | . | . | . | X | X | . | . | . | . |
AUTO SP | . | . | . | X | X | . | . | . | . |
DTE SP | |||||||||
64.0K | . | . | . | . | . | . | . | X | X |
57.6K | . | . | . | . | . | . | . | . | X |
56.0K | . | X | X | X | X | X | X | . | . |
38.4K | X | X | X | X | . | . | . | . | X |
19.2K | X | X | X | X | X | . | . | . | X |
9.6K | X | X | X | X | X | . | . | . | X |
4.8K | . | X | X | X | . | . | . | . | . |
2.4K | . | X | X | X | . | . | . | . | . |
1.2K | . | X | X | X | . | . | . | . | . |
RATE ADAPT | X | X | X | X | . | . | . | . | X |
SYNC | X | X | X | X | X | X | X | X | X |
ASYNC | X | X | X | X | X | . | . | . | X |
RS-232 | X | X | X | X | X | X | . | X | X |
V.35 | X | X | X | X | X | X | X | X | X |
INTERN MUX | 4CH | 2CH | . | . | . | . | . | . | . |
AUTO EQUAL | X | X | X | X | X | X | X | X | X |
DIAG | |||||||||
DIG LOOP | X | X | X | X | X | X | X | X | X |
SELF TST | X | X | X | X | X | X | X | X | X |
LINE LP | X | X | X | X | X | X | X | X | X |
PAT GEN | X | X | X | X | X | X | X | X | X |
TELCO | X | X | X | X | X | X | X | X | X |
REMOTE | X | X | X | X | X | X | X | X | X |
I/O LED'S | X | X | X | X | X | X | X | X | X |
TST LEDS | X | X | X | X | X | X | X | X | X |
LIFETIME WARRANTY | X | X | X | X | X | X | X | X | X |
ADV SPARE | X | X | X | X | X | X | X | X | X |