Modem
VDC power
Hardened
Industrial Grade for Business, Utility and Industrial applications including
Digital, dial up - leased line - cellular/cell modems.
VDC & VAC POWERED
Data
Connect ( formerly Telenetics ) has
designed modems that work in "remote" remote sites with very low
failure rates. These devices work where other modems roll over and die. When a
service call to a remote site can mean an all day trip these modems are the
ideal solution.
(Ask
us about the new
202T
DC powered
modem)
|

|
-
5VDC
to 220/240VAC Power Supply
-
IEC801-4/5 Surge
Protection
-
-40oC
to +85oC
Operating Temp.
-
RTU, Meters, Relays,
SCADA
-
Solar
Powered Applications
|
MIU
MODEMS
300bps to 28.8kbps
To service the growing need for
efficient, reliable data communications in the harsh environments of
"remote" remote sites and industrial facilities. Data Connect (
formerly Telenetics ) has
developed a family of data communications products that can operate from
various AC & DC power supplies and survive high surge levels and extreme
heat and cold. All this without compromising the performance expected from
state-of-the-art communications devices.
Dial-Up
& Leased line
With the rapid move toward
"intelligent" remote sites, where meters, relays, RTU’s, SCADA
systems, etc. are able to "talk" via communications devices such as
Cellular modems with out the conveniences of 115VAC power outlets and climate
control.
Data Connect ( formerly Telenetics ) Corp., a leader in the
"industrial" communications market place, has developed a range of
communication devices designed specifically to operate reliably in these harsh
environments.
Data Connect ( formerly Telenetics ) has designed modems that work
in "remote" remote sites with very low failure rates. These devices
work where other modems roll over and die. When a service call to a remote site
can mean an all day trip these modems are the ideal solution.
The MIU2.4, 9.6, 14.4 and 28.8 are highly
sophisticated full duplex, Bell 103, Bell 212A, V.22bis, V.32bis or V.34
data/fax modems that are designed to interface with RS232, 5V logic (TTL) or
simple send and receive signals. They operate at full or half duplex on dial-up
or 2-wire leased line systems. 4-wire leased line models are also available.
These modems are powered from a patented power
supply that enables them to operate on any voltage from 9 to 36VDC or 48
to 220VAC or DC. They are also designed to work in temperatures ranging from -40oC
to +85oC, and are surge protected to double the voltage requirements
of IEC801-4.
Options include
RS422 and RS485 interfaces, 5/12/24/48VDC power supply, and additional surge
protection (IEC801-5).
| Technical
Specifications
|
MIU2.4
|
MIU9.6
|
MIU14.4
|
MIU28.8
|
| Modem
Line Speeds:
Asynchronous
|
2400, 1200, 300bps
|
2400, 1200, 300bps
|
14400, 9600, 4800, 2400,
1200, 300bps
|
28800, 14400, 9600,
4800, 2400, 1200, 300bps
|
| DTE
Rates: |
2400, 1200, 300bps
|
19200, 9600, 4800bps
with data compression
|
57.6, 38.4,
19.2kbps
with data compression
|
115.2, 57.6, 38.4,
19.2kbps with data compression
|
| Modulation |
V.22bis
V.22
Bell 212A
Bell 103 |
V.22bis,
V.22
Bell 212A
Bell 103 |
V.32bis,
V.32 V.22bis, V.22 Bell212A
Bell103 |
V.34
V.32bis,
V.22bis, V.22
Bell212A
Bell103 |
| Dial
Up and |
MIU2.4
|
MIU9.6
|
MIU14.4
|
MIU28.8
|
| 2
& 4 Wire Leased Line |
n/a
|
MIU9.6L
|
MIU14.4L
|
n/a
|
| Compatibility |
Hayes™ Extended AT
Command Set
|
| Error
Correction/
Data Compression
|
None
|
MNP 2, 4, 5 & 10
V.42, V.42bis
|
| Power
Supply |
48VAC/DC to 220VAC/DC
(Optional 9 to
36VDC - use "LV" Low Voltage)
|
| Power
Connector |
3-Pin with Screw
Terminals for Customer Supplied Cable
(Cable available from
Data Connect ( formerly Telenetics ) if required)
|
| Size |
5-3/8" x 4" x
1-3/8"
|
| Data
Port |
RS232 with DB9 Connector
|
| Telco
Ports |
RJ11
|
| Surge
Protection
(Power Line)
|
8kV [Exceeds
IEC801-4]
(20kV [IEC801-5]
available if required)
|
| Surge
Protection
(Telco/Interconnect)
|
5kVac
|
5kVac
|
3.75kVac
|
3.75kVac
|
| Operating
Environment |
-40oC to +85oC,
0 to 95% humidity (non-condensing)
|
| Certifications |
FCC Part 68 Class A,
Industry Canada
|
Low Voltage Option LV (9 to
36VDC )
* Fax not available on 4-wire leased line models
...Standard Features...
| Model |
Serial Interface
|
Power Supply
|
Power Connection
|
Options
Available
(SeeTable Below)
|
| MIU2.4
MIU9.6
MIU14.4
MIU28.8
|
RS232
|
48-220VAC or VDC
"LV"
option
LOW VOLTAGE
9 to 36VDC
|
3-Pin Connector
without cable
|
1, 2, 3, 4,
5, 7
|
(Ask
us about the new 202T
DC powered modem)
Voltage
Supply:
Standard Model:
MIU
40 to 270VDC 40 to 270VAC, 50/60Hz
LV Model (Suffix
"-LV"): 9 to 36VDC
(Suffix
"-LV"): 9 to 36VDC
Current
Requirements:
MIU2.4:
- 12VDC 24VDC 125VDC 120VAC
220VAC
- 65mA 27mA 7.5mA 6.5mA
5.5mA
MIU9.6:
- 12VDC 24VDC 125VDC 120VAC
220VAC
- 115mA 57mA 11mA 10mA 9mA
MIU14.4:
- 12VDC 24VDC 125VDC 120VAC
220VAC
- 160mA 69mA 14mA 12mA 9mA
MIU28.8:
- 12VDC 24VDC 125VDC 120VAC
220VAC
- 205mA 125mA 16mA 15mA 11mA
Surge Protection: Power
Supply: 8kVrms
Analog Line: 5kVac (MIU2.4
& 9.6) - 3.75kVac (MIU14.4 & 28.8)
|
Available Options...
|
Item
|
Description
|
Order Suffix
|
|
1
|
RS422 Serial
Interface |
-422
|
|
2
|
RS485 Serial
Interface |
-485
|
|
3
|
9
to 36VAC/DC Power Supply |
-LV
|
|
4
|
4 Foot Power
Cable |
-C
|
|
5
|
4 Foot Power
Cable (High Surge) |
-HC
|
|
6
|
Type ST Fiber
Optic Cable Connections |
-ST
|
|
7
|
Auto Dialer |
-AD
|
Order Code Example: MIU2.4-485-LV-AD
2400bps Modem
With Optional RS485 Interface
With Optional 9-36VDC Power Supply
With Optional Auto-Dialer
|