ISDN Terminal

banner
Optimum connectivity for your ISDN terminal equipment.

Features & Benefits | Specifications

Transparently converts a 2-wire "U" interface line code (central office/network) to a 4-wire "S/T" alternate space inversion code (terminal/customer site).
U interface fully complies with ANSI standard T1.601-1992, S/T interface with ANSI standard T1.601-1991.
Desktop or wall-mount for added flexibility-can also be mounted in a wiring closet!
Versatile support of both point-to-point and multipoint operation.
Automatic remote (backup) power pickup, local power loss "dying gasp" notification, and built-in surge protection.

Operation
Network Termination 1 (NT1) unit providing interface between ISDN network and ISDN terminal equipment in both point-to- point and multipoint configurations.
Line Rate
192 kbps.
Line Interface
Two 8-pin modular (RJ45). U interface, ANSI T1.601-1992. Maximum length: 18,000 feet on 26 gauge wire.
Customer Interface
8-pin modular (RJ45). S/T interface, ANSI T1.601-1991.
Size
6 in. (W) x 5 in. (H) x 1.5 in. (D); Wt.: 2.5 lbs.
Power
120 VAC; 5 Watts.
Supplied
Wall-mount transformer; RJ11C to RJ45 cable (6 ft.) for U interface.