Adtran Total Access OPTI-3
Controller Module
1184002L3 SOI4JN3DAA
Adtran Total Access OPTI-3
Controller Module 1184002L3 SOI4JN3DAA
- SONET OC-3LR-1 optical interface
- Rate: 155.52 Mb/s
- Span length: Long Reach, 40 km
- Wavelength: 1310nm (nominal)
- Dual SC optical connections
- Framing, multiplexing and mapping compliant with SONET standards
- OC-3 facility and equipment loopback
- Detects and indicates standard optical and SONET related alarms and
conditions
- SONET level performance monitoring
- SONET line protection switching
- 1+1 equipment and facility protection for optical network interface
- 1:1 equipment protection for optical network interface
- Maximum 60ms protection switching time (OC-3 to low speed interface)
- Board-mounted manual APS control switch
- Provide three Clear Channel DS3 Signals (via BNC connectors)
- Two external DS1 BITS clock interfaces
- Three sense points including AUX1, AUX2, and AUX3
- Fully hot swappable
- External BITS, line, or free-run timing modes
- SONET Minimum Clock (SMC) with +/- 20 ppm accuracy
- OAM&P via data communication over Section DCC channel
- Support SONET section DCC bridging
- Controller cards Cross Copy Communication Link
- OAM&P interface via craft interface (DB-9)
- TL1, Telnet, SNMP, and TFTP over Ethernet
- Supports Software downloads locally via craft interface (DB9) and TFTP
over Ethernet. Remote TFTP and YModem downloads supported when configured for
Back-to-Back IP mode.
- TL1 management support
- Supports TL1-based GUI network management interface
- Provides 3 DS3 interfaces.
- Software-controlled DS3 Transmit Level Control
- Automatic Receive Equalization
- Software-controlled Remote and Local DS3 Loopback capability
- Monitors incoming Receive Signal for LOS (Loss Of Signal)
- Monitors the Receive Analog and Digital LOS
- Monitors Transmit Output signal for drive failure
- LED status indicators:
- Board Status (Power/Fail)
- Optic Status (LOL, LOF, etc.)
- DS3 #1 Status
- DS3 #2 Status
- DS3 #3 Status
- ACO
- External ACO input (RMC only)
- Three audible alarm outputs including Critical, Major, and Minor (RMC
only)
- Three visual alarm outputs including Critical, Major, and Minor (RMC only)
- –20 VDC to –60 VDC input voltage range
- +20 VDC to +60 VDC input voltage range
- Power consumption between 7 and 10 watts (typical) per OCM
- Operating temperature range of −40°C to +65°C (installed in RMC)
- Operating temperature range of −40°C to +50°C (installed in WMC)
- Storage temperature range −40°C to +85°C
- Relative humidity up to 95 percent, noncondensing
- NEBS Level 3, GR-1089-CORE, GR-63-CORE and UL60950 compliant
- Meets applicable optical and SONET standards (GR-253, T1.101, T1.105.xx)